How to choose between TKD-F ultrasonic heat meter and TKD-H electromagnetic heat meter?

Choose ultrasonic type for clean water and household metering; select electromagnetic type for main pipelines and water with impurities for high-precision settlement.

What pipe diameters do heat meters support?

TKD-F covers DN15~DN1000, suitable for household, park and geothermal energy station pipelines.

What is the difference between energy valve and ordinary heat meter?

TKD-N energy valve integrates metering and electric regulation to control flow and measure cooling & heating energy for energy saving.

Which metering devices are recommended for hospital projects?

Electromagnetic heat meters and 4G wireless thermostats with strong anti-interference performance fit medical environments.

Ultrasonic or electromagnetic heat meter for geothermal cooling systems?

Electromagnetic heat meter is preferred for primary geothermal pipelines with good scale resistance.

Time-based or energy-based billing for central air conditioning in apartments?

Time thermostats for budget needs; energy heat meters for fair and accurate charging.

Scenarios for LoRa and 4G thermostats?

LoRa for centralized buildings; 4G thermostats for scattered shops and independent buildings.

Differences between TKD-S600W and TKD-S600L thermostats?

W stands for wireless transmission, L for wired RS485 communication for different wiring conditions.

Which thermostat matches DC brushless fan coil units?

Special TKD-S600F thermostat supports speed regulation signals of DC brushless fans.

Suitable billing collectors for split air conditioners?

TKD-A/B time recorders detect fan gears and record operating hours.

Energy monitoring terminal for large commercial complexes?

TKD-X920 multi-functional touch terminal collects temperature, humidity and other data.

Heat meter for DN15 household heating pipes?

Threaded ultrasonic household heat meter features easy installation without pipe reconstruction.

Can ordinary heat meters be used for industrial high-temperature geothermal pipelines?

Custom high-temperature sensors are required; standard models adapt to medium temperature below 95℃.

Is pre-payment function only available on thermostats?

Energy valves, heat meters and cloud platforms all support pre-payment and power-off functions.

Are clamp-on ultrasonic meters suitable for old community pipe reconstruction?

Yes, they need no pipe cutting to shorten construction period and cost.

Can energy valves adjust hydraulic balance independently?

Yes, the system can remotely adjust valve opening to balance pipe network flow automatically.

Does the billing system match VRF multi-connected air conditioners?

Matched time collectors convert fan operating data into energy consumption fees.

Complete metering solution for high-efficiency cold stations?

Integrated solution of electromagnetic heat meter, multi-functional terminal and energy cloud platform.

Does the waterproof level adapt to underground garage pipelines?

The whole meter reaches IP65 waterproof level for stable operation in humid environment.

What is the turndown ratio? Will low flow cause inaccurate measurement?

100:1 turndown ratio ensures accurate measurement even under extremely low flow without blind area.

What problems will happen if the heat meter is installed in reverse flow direction?

Flow and energy data will be disordered and energy accumulation fails.

Installation standards for temperature sensors?

Sensors must be placed in the pipe center; supply and return sensors cannot be exchanged.

Straight pipe section reservation for electromagnetic heat meters?

10 times pipe diameter at the front and 5 times at the rear for stable full pipe measurement.

Will air bubbles affect metering accuracy?

Yes, bubbles cause flow fluctuation; exhaust valves shall be installed at high points.

Long-distance wiring for split heat meter integrators?

Standard sensor wire is 10 meters; customized shielded wires are needed for longer distance.

Independent power supply required for thermostat wiring?

Wired models take power from fan coils; 4G wireless ones only need live wire and neutral wire.

Valve requirements for energy valve installation?

Maintenance ball valves shall be installed on both sides for later maintenance and replacement.

Can weak current communication wires be laid together with power cables?

Not recommended, to avoid electromagnetic interference from frequency conversion equipment.

Can heat meters be installed vertically?

Ultrasonic meters support all angles; electromagnetic ones are better installed horizontally.

Hidden dangers without pre-filter installation?

Impurities will block sensors and shorten service life greatly.

Moisture-proof measures for meters in underground machine rooms?

Install waterproof boxes and seal wiring terminals tightly.

Maximum networking distance of LoRa thermostats?

1km in open areas; add repeaters within 500 meters with wall barriers.

Will pipe thermal insulation block temperature sensors?

Reserve installation openings to avoid temperature measurement deviation.

Solutions for joint water leakage of heat meters?

Replace sealing gaskets and fasten flanges evenly.

Install meters before or after pipe flushing?

Install meters after pipe flushing to prevent sensor scratch.

Standard installation height of multi-functional terminals?

1.3 to 1.5 meters above ground for easy operation.

High temperature resistance of temperature measuring wires for geothermal wells?

Standard wires resist 105℃; special high-temperature wires for ultra-high temperature

Will repeated device IDs cause remote transmission failure?

Yes, it leads to data disorder; check numbers before system entry.

Will wrong fan coil wiring burn thermostats?

Wrong wiring triggers protection and may damage main boards seriously.

Influence of inclined energy valve actuators?

Valves must be horizontal to avoid valve core jamming and regulation failure.

What billing modes are available for central air conditioning?

Energy metering mode, time conversion mode and energy valve control billing mode.

Does the platform support time-of-use tiered charging?

Yes, it supports differentiated prices for working days, weekends and overtime periods.

Will air conditioners be cut off immediately after pre-payment arrears?

It supports balance early warning, overdraft limit and power-off delay protection.

Can residents check air conditioning bills via mobile phones?

WeChat mini-program supports real-time data checking, recharge and bill inquiry.

Can the system export Excel charging reports?

Monthly, quarterly and annual reports are available for property financial reconciliation.

Is data deviation between main meters and branch meters normal?

Deviation within ±3% is reasonable; check valve leakage and installation problems for larger errors.

How does time-based billing distinguish fan speed energy consumption?

Built-in coefficient algorithm converts high gear operation into more equivalent duration.

Meanings of positive and negative energy values?

Positive for cooling energy, negative for heating energy with independent statistics.

Will data be lost during network disconnection?

Local devices store 6-month data and automatically upload after network recovery.

Does it support two-part charging of basic shared fee plus metering fee?

Yes, complying with national two-part heating and cooling charging standards.

Can administrators remotely adjust temperature limits in batches?

Background one-click parameter issuing limits cooling and heating temperature ranges.

How to clear account balance after tenant check-out?

Background supports account reset and refund record filing with full traceability.

Does the platform support unified management of multiple projects?

Cloud SaaS platform manages hospital, park and office building projects centrally.

Can energy data connect with existing property ERP systems?

Standard API interfaces are provided for third-party system data docking.

Functions of CO₂ data displayed on terminals?

It assists fresh air control to reduce ventilation energy consumption and improve comfort.

Functions of regional energy hosting system?

It assists fresh air control to reduce ventilation energy consumption and improve comfort.

Does the system automatically generate energy-saving analysis reports?

Monthly energy-saving reports locate high-energy-consumption rooms and idle equipment.

Can energy meters and time-based devices realize unified billing?

The platform is compatible with both types to complete unified accounting and billing.

Are extra fees required for remote air conditioner control?

Basic cloud platform functions are free of additional communication service fees.

Is cloud data storage safe and available for backup?

Encrypted cloud storage supports local data export and backup for compliance retention.

Reasons for blank screen of heat meters?

Battery exhaustion, water inflow or main board damage needs battery replacement or factory repair.

Normal on-site display but no data received by platform?

Broken communication lines, wrong device ID or offline gateway need troubleshooting.

Troubleshooting for long-term zero instantaneous flow?

Fully closed valves, reversed installation, pipe blockage or falling-off sensors.

Solutions for temperature measurement error codes E1/E2?

Broken or damaged supply and return temperature sensors need matched replacement.

Adjustable temperature but no deduction record on thermostats?

Broken fan gear acquisition lines fail to record operating duration.

Failure of remote control and adjustment of energy valves?

Power supply failure, 485 circuit short circuit or valve core jamming.

Online gateway but offline partial thermostats?

Excessive distance or wall shielding requires signal repeaters.

Excessively high cooling and heating metering values?

Excessive air bubbles and shallow sensor installation need exhaust and re-fixation.

Repairable meters with water-corroded main boards?

Slight corrosion can be repaired; severely damaged ones need integrator replacement.

Will faults trigger automatic reminder push?

The platform sends fault alarms via SMS and WeChat for rapid maintenance.

Unstable jumping readings of heat meters?

Pipe air blockage leads to data fluctuation; install exhaust valves and recalibrate.

Air conditioners still power off after successful pre-payment recharge?

Synchronize balance data via background instructions to recover power supply.

Solutions for decreased metering accuracy after long-term use?

Send to metering institutions for verification and replace sensors beyond error range.

Flow record even when end valves are closed?

Internal leakage of end valves needs sealing valve maintenance and replacement.

Solutions for unresponsive touch screens of multi-functional terminals?

Power off and restart; replace touch panels for frequent failure.

Do heat meters have national CPA metering certificates?

All energy metering products obtain CPA certificates for trade settlement use.

Are products certified by ISO9001 quality management system?

The whole company processes comply with ISO9001 with annual third-party audit.

Mandatory verification cycle of heat meters?

According to JJG225 regulations, the verification cycle shall not exceed 6 years.

Required qualification documents for hospital bidding projects?

CPA certificates, test reports, ISO certificates and specialized enterprise certificates.

Is Tikind a specialized and sophisticated enterprise?

It has passed repeated review as Shenzhen specialized and sophisticated SME.